Biochemical oxygen demand bod is the amount of dissolved oxygen needed i. Dissolved oxygen demand do and chemical oxygen demand cod pdf 1. The national field manual for the collection of waterquality data nfm is an online report with separately published chapters that provides the protocols and guidelines by which u. All organic compounds may convert into carbon dioxide, water and ammonia. Chemical oxygen demand cod india environment portal. Biological oxygen demand is a widely used technique to express the concentration of organic matter in waste water samples. By john stone chemical oxygen demand cod is a quick, inexpensive means to determine organics in water. Oxygen demand is a measure of the amount of oxidizable. Geological survey personnel obtain the data used to assess the quality of the nations surfacewater and groundwater resources. Chemical oxygen demand cod is an important parameter for wastewater or surface water testing and plants. Wastewater commonly contains organic compounds, as a result of industrial processes, which can oxidise in the presence of dissolved oxygen in the water.
Biochemical oxygen demand is a measure of the microbial consumption of. Longitudinal profiling of dissolvedoxygen concentrations during the spring and summer of 1996 revealed dissolvedoxygen minimums occurring upstream from the pointsource discharges. Running water, because of its churning, dissolves more oxygen than still. Chemical oxygen demand indicates the amount of oxygen required to oxidize all soluble and particulate organic substances in water under specific conditions. Organic matter is oxidized into carbon dioxide and water in an acidic condition. Biological oxygen demand bod india environment portal. Experiment 5 biochemical oxygen demand objectiveto determine biochemical oxygen demand of the given unknown water sample. Program and regulatory information about this substance, including links to epa applicationssystems, statuesregulations, or other sources that track or regulate this substance. Oxygen demand, chemical oxygen demand, chemical page 5 of 6 estimated detection limit edl the edl for program 432 is 4mgl cod. Certain environmental stresses hot summer temperatures and other humaninduced factors introduction of excess fertilizers to a water body can lessen the amount of dissolved oxygen in a water body, resulting in stresses on the local aquatic life.
Geological survey, 2795 anderson avenue, suite 106, klamath falls, or 97603, usa article info abstract article history. The level of oxygen concentration in water bodies, expressed as biochemical. D dissolved oxygen demand and chemical oxygen demand chetan singh pundeer 12 ce 036 chetan singh pundeer 12 ce 036 1 2. Now customize the name of a clipboard to store your clips. Clipping is a handy way to collect important slides you want to go back to later. Biological oxygen demand is an important water quality parameter because it greatly influences the concentration of do that will be in the water. The edl is the calculated lowest average concentration in a deionized water matrix that is different from zero with a 99% level of confidence. Theoretical oxygen demand thod is the calculated amount of oxygen required to oxidize a compound to its final oxidation products. Oxygen demand is a measure of the amount of oxidizable substances in a water sample that can lower do concentrations nemerow, 1974. Biochemical oxygen demand is the amount of oxygen required for microbial metabolism of organic compounds in water. How to determine biochemical oxygen demand in water and wastewater. It is a measure of the amount of dissolved oxygen used by microorganisms in the water.
Testing oxygen demand has its widest application in measuring waste loadings of treatment plants and in evaluating treatment efficiency. At room temperature, the amount of oxygen dissolved in water is 8 mgl. The cod test is often used to monitor water treatment plant efficiency. Characterization of water quality and simulation of. In this case, the demand for oxygen will be high due to all the bacteria so the bod level will be. Oxygen demand is a measure of the amount of oxidizable substances in a water sample that can lower do concentrations. The decay of organic matter in water is measured as biochemical or chemical oxygen demand. This application note concerns cod determination by potassium dichromate. Since the implementation of the clean water act and subsequent creation of the united.
Unesco eolss sample chapters environmental and ecological chemistry vol. Chemical oxygen demand titrimetric, high level for saline waters by titration. If there is a large quantity of organic waste in the water supply, there will also be a lot of bacteria present working to decompose this waste. Cod of wastewater or domestic water supply is found to be greater than or equal to a value of 0. Method specified is applicable to water with a value between 30 mgl and 700 mgl.
Chemical oxygen demand testing is typically performed using a strong oxidizing chemical. The science of chemical oxygen demand technical information series, booklet no. Application of photoelectrochemical chemical oxygen demand to drinking water amina k. Geological survey entered into a cooperative agreement with the kershaw county water and sewer authority to characterize and simulate the water quality in the wateree river, south carolina. Add 2ml of manganese sulfate to the bod bottle carefully by inserting the pipette just below the surface of water. Biochemical oxygen demand bod is an empirical test to provide a measure of the level of degradable organic material in a body of water. The haryana state pollution control board hspcb has issued showcause notices to 14 large and mediumscale industrial units for releasing untreated water. Biochemical oxygen demand bod and concentration of ammonium in. Biochemical oxygen demand, dissolved oxygen, selected nutrients, and pesticide records of texas surface waters, 1968 introduction data presented in this report were collected as a part of continuing statewide water qualityinvestigations by the u. Because of its unique chemical properties, the dichromate ion cr2o7. Replacement of chemical oxygen demand cod with total organic carbon toc for monitoring wastewater treatment performance to minimize disposal of toxic analytical waste. Organic pollution in water can be monitored by measuring an important index called chemical oxygen demand cod.
This report summarizes results from a study conducted from june 2006 april 2007 that i quantified nutrient release from sediments in the lake, ii determined sediment and water oxygen demand, and iii evaluated the suitability and effectiveness of different inlake nutrient control strategies. This determination gives information about the degree of water pollution by organic material. Cod samples are prepared with a closedreflux digestion followed by analysis. The quantity of oxidant consumed is expressed in terms of its oxygen equivalence. Add 2 ml of alkaliiodideazide reagent in the same manner. So the amount of dissolved oxygen in the water is an indicator of the quality of water. General discussion the biochemical oxygen demand bod determination is an empirical test in which standardized laboratory procedures are used to determine the relative oxygen requirements of wastewaters, ef. For more information about the substance, you may click one of the links below to take you to the relevant section. By definition, chemical oxygen demand is a measure of the oxygen equivalent of the organic matter content of a sample that is susceptible.
So that you can avoid the formation of air bubbles. Running the biochemical oxygen demand bod test ebs. Pdf statistical evaluation of biochemical oxygen demand of river. Microorganisms use the atmospheric oxygen dissolved in the water for biochemical oxidation of organic matter, which is their source of carbon. Epa on march 31, 2005 for wastewater compliance monitoring. Pdf replacement of chemical oxygen demand cod with. Sediment nutrient flux and sediment oxygen demand in. The samples are allowed to cool for 10 minutes and then titrated. This test is based on the fact that a strong oxidizing agent, under acidic conditions, can fully oxidize almost any organic compound to carbon dioxide. Determinations can be made titrimetrically by several approved methods, or.
A cod test can be used to easily quantify the amount of organics in water. Water analysis using lambda chemical oxygen demand. Geological survey, 2 sw 5th avenue, portland, or 97201, usa b u. Dissolved oxygen concentrations indicate how well aerated the water is, and vary according to a number of factors, including season, time of day, temperature, and salinity.
Alternative seeding, dilution, and incubation conditions can be chosen to mimic receivingwater conditions, thereby. The values of biochemical oxygen demand obtained are characteristic of unpolluted waters which suggest that the municipal effluents discharged into the. Introduction bod is defined as the amount of oxygen required by living organisms in the stabilization of the organic matter of water. It is a significant parameter to determinate water characteristic. Biological oxygen demand bod is a measure of the oxygen used by microorganisms to decompose this waste. Mihelcic encyclopedia of life support systems eolss commonly used in wastewater treatment and surface water. Apart from oxidizable materials, waste materials from domestic and industrial sources can also exert demand for oxygen. Notice to 14 industrial units for flouting pollution norms.
Biochemical oxygen demand in water bodies fresh water. Biochemical oxygen demand measures the amount of oxygen consumed in the water by chemical and biological processes. In environmental chemistry, the chemical oxygen demand cod is an indicative measure of the amount of oxygen that can be consumed by reactions in a measured solution. The kinetics of dissolved oxygen consumption resulting from bod discharges have been formulated into several mathematical models for simulating surface water. Chemical oxygen demand cod is used as an indirect measurement of the sum of oxidizable matter in water and measures the equivalent amount of oxygen required to oxidize organic compounds. The chemical oxygen demand cod is a measure of water and wastewater quality. The biochemical oxygen demand bod test is a measurement of the quantity of oxygen required by bacteria to biologically oxidize organic material under aerobic conditions. Chinas overall water quality improved in the first half of this year, with 70 percent of groundwater samples taken from around the country deemed fit. Chemical oxygen demand cod extension to vecl against supreme court order. To determine bod, the amount of oxygen the bacteria use is calculated by comparing the amount left at the end of five days with the amount known to be present at the beginning. Chemical oxygen demand cod is the amount of oxygen consumed by the organic compounds and inorganic matter which were oxidized in water. Biochemical oxygen demand bod is usually expressed in mgl but can also be expressed in lbsday. Biochemical oxygen demand, dissolved oxygen, selected. For greatest accuracy it is preferable that the value of the sample is in the range of 300 mgl to 600 mgl.
Biochemical oxygen demand bod is a measure of the dissolved oxygen consumed by microorganisms during the oxidation of reduced substances in waters and wastes. The quantity of organic matter or the demand of oxygen is calculated by determining how much oxidizing chemical was. Carefully fill a bod bottle with sample water without making air bubbles. However, there are some differences between standard methods that can influence the results obtained.
Dissolved oxygen refers to the level of free, noncompound oxygen present in water or other liquids. To understand the need for seeding in the bod test c. If the value exceeds 700 mgl, the water sample is diluted. Biochemical oxygen demand bod and concentration of. Pdf dissolved oxygen and biochemical oxygen demand in the. The carbohydrates cellulose, starch, sugars, proteins, petroleum hydrocarbons and other materials that comprise organic matter get into water from natural sources and from. Dissolved oxygen demand do and chemical oxygen demand. Total bod is of more significance to food webs than to water quality. A dilution system ensures rapid responses to biological oxygen demand fluctuations, and protects and stabilizes the microbe population. Water analysis instruments 01915 9782326015 chemical oxygen demand thermo orion method codl00 and codh00 revision 5, 03252005 accepted by u. Simultaneous determination of chemical oxygen demand. This demand occurs over some variable period of time depending on temperature, nutrient concentrations, and the enzymes available to indigenous microbial populations. If the oxidation of an organic compound is carried out by microorganisms using the organic matter as a food source, the oxygen is consumed. The measuring system incorporates a bioreactor populated with microorganisms adapted to the wastewater stream.
A simple comparative study of evaluation of biochemical oxygen demand bod of river water of gangas has been developed. Biological oxygen demand bod, also known as biochemical oxygen demand, is a bioassay procedure that measures the dissolved oxygen do consumed by bacteria from the decomposition of organic matter. National field manual for the collection of waterquality. High bod levels are associated with excessive plant growth and decay and high amounts of other organic matter in a river or stream. Application of photoelectrochemical chemical oxygen. Cod test the chemical oxygen demand cod test uses a strong. A seasonal assessment of groundwater pollution due to. Controls on biochemical oxygen demand in the upper klamath. Biochemical oxygen demand bod 5day primary importance. Application report the importance of biochemical oxygen. Biological oxygen demand measures the amount of oxygen used by microorganisms in the oxidation of organic matter. Biochemical oxygen demand bod is the amount of oxygen, expressed in mgl or parts per million ppm, that bacteria take from water when they oxidize organic matter. The biochemical oxygen demand bod determination is an empirical test in which standardized laboratory procedures are used to determine the relative oxygen requirements of wastewa ters, ef. Biological oxygen demand bod5 is the amount of oxygen consumed by the organic and inorganic compounds which were oxidized by biologicaloxidation effect in a certain condition.
594 622 1338 782 1121 1054 630 1517 1489 1136 1272 633 776 1240 247 611 288 935 124 1396 238 188 270 241 19 701 1313 225 1095 345 20 460 123 652 355 698 125 461 1072 502 924 459 969